Question
the values of the resistors in the AD688 and the ways to compensate the voltage
reference temp drift by using temp sensors.
Answer
R1= 5K
R2 = 10K
R3 = 150k
R4 = 6.3k
R5= 13.7k
R6 = 150k
Question
the values of the resistors in the AD688 and the ways to compensate the voltage
reference temp drift by using temp sensors.
Answer
R1= 5K
R2 = 10K
R3 = 150k
R4 = 6.3k
R5= 13.7k
R6 = 150k