Does the MAX7413 internal clock automatically start up when an external capacitor is connected to the CLK pin?
Yes, the MAX7413 internal oscillator will start up as soon as an external capacitor is connected or when an external clock source is applied to the CLK pin. The switched capacitor filter will not operate properly until an external clock source or capacitor is connected.