Search FAQs on the left to see if your question has been answered. Click on the dropdown to view all of the documents associated with the product. If you can't find your question, click on Ask a Question

ADV7182 Datasheet Default Values

Hello All,

Unfortunately there are some mistakes in the ADV7182 rev C datasheets regarding the default value of some registers. These mistakes will be fixed in the next revision of the datasheet.

  • User Map register 0x11 (IDENT) has the default value of 0x41.
    • An incorrect value is given in Table 92 of the ADV7182 datasheet rev C.
  • User map register 0x31 (VS/FIELD Control 1) has the default value 0x02
    • An incorrect value is given in table 95 of the ADV7182 datasheet rev C.
  • User Map register 0x37 (Polarity) has the default value of 0x81.
    • An incorrect value is given throughout the ADV7182 datasheet rev C.

Also note that User Map register 0xC4 (ADC Switch 2) has the default value of 0b'0xxxxxxx . Where x is a don't care term.

Regards,

Robert Hinchy

Senior Applications Engineer,

Analog Devices Inc.

Comments