ADXRS290: FAQ

  • Created
  • Updated
Was this helpful?
  • 3-axis Gyroscope

    Question Are there plans to release a 3-axis gyro, similar to the ones found in your IMUs, for example ADIS16488A. Answer The ADIS16488A uses discrete, single-axis gyroscopes, on vertical and horizontal…
  • Bandwidth

    Question Can I get bandwidth greater than 480Hz? Answer The maximum bandwidth achievable is 480Hz (see datasheet). Applications demanding bandwidth larger than this value will require external feedback…
  • Best way to evaluate the ADXRS290

    Question What is the best way to evaluate the ADXRS290? Answer Two options are available:· A complete, GUI-based system (EVAL-ADXRS290Z-M) is available for viewing real-time data and familiarizing oneself…
  • Does the ADXRS290 have a FIFO?

    Question Does the ADXRS290 have a FIFO? Answer The ADXRS290 does not have a FIFO. Applications that require a FIFO will have to implement one external to the gyroscope, and can use the SYNC/ASELpin (pin…
  • Evaluation of ADXRS290

    Question What is the best way to evaluate the ADXRS290? Answer Two options are available:· A complete, GUI-based system (EVAL-ADXRS290Z-M) is available for viewing real-time data and familiarizing oneself…
  • Group delay associated with the internal configurable band-pass filter

    Question What is the group delay associated with the internal configurable band-pass filter? Answer The ADXRS290 includes an internal configurable band-pass filter. Both the high-pass and low-pass poles…
  • Implemention of interrupt driven wake-up functionality for the ADXRS290

    Question How can I implement interrupt driven wake-up functionality for the ADXRS290? Answer There is no hardware interrupt capability implemented in the ADXRS290. To set the part to measurement mode,…
  • Low-noise yaw gyroscope with ADXRS290

    Question The ADXRS290 is a roll/pitch gyroscope. What should I do to obtain a low-noise yaw gyroscope? Answer For a roll/pitch/yaw (3-axis) solution, the customer needs to use at least 2 separate ADXRS290…
  • Measurement range

    Question The ADXRS290 datasheet mentions that the output full scale range is ±100°/s. Will the part get damaged if it encounters a larger rotation rate? Answer The measurement range in the datasheet indicates…
  • Offset drift on the ADXRS290

    Question What is the offset drift on the ADXRS290? When should I be worried about offset drift for my application? Answer Offset drift is an important parameter for gyroscopes, especially where they are…