Article Question about MAX20327 continuous current.

Question:

MAX20327 absolute maximum ratings list continuous current 1.1A and 50% duty cycle peak current 1.6A. What about peak current capability of low duty cycle current? For example 100ns 2.7A current with 10ms period?

 

Answer:

Such low duty cycle will not be a problem to MAX20327 on either thermal or voltage drop.