• LTC4079 Linear Battery Charger

    Hi,

    I am using LTC4079 in the battery backup system of my design to charge Li-Ion batteries. The input and output voltages of LTC4079 are 24 V and 4.2 V, respectively. If there are fluctuations in the input voltage, let's say it drops down to 16V from…

  • LTC4079 - not running in timer mode with cap on timer pin

    Hello,

    I have the LTC4079 up and running and am trying to bench test it as I integrated it into my product.  I want to use the part in timer mode and from what I understand from the datasheet this is achieved by loading a capacitor on the timer pin.  I…

  • LTC4079E Li-ion IFR battery

    Hi,

    I am using LTC4079 for charging LiFePo4 battery. The battery can be charged at 7.2V but I noticed that when charging is enabled LTC4079 outputs 7V only. I followed recommendation from datasheet to use 1% resistor 1.37M and 267K.

    Could anyone explain…

  • RE: Looking for Battery Charger IC

    Hi Kazu,

    I found the LTC4079 which has a thermal regulation function. Please take a look and review if it can be used in your desired application. LTC4079 Datasheet and Product Info | Analog Devices

  • RE: Charging and protection for a LIR2032 cell: LTC4071

    You can use the LTC4071 for this application; note that the charging current will vary depending on the input voltage (see charge-current equation on datasheet, p. 7).  You may wish to consider the LTC4079.  https://www.analog.com/media/en/technical-documentation…

  • RE: Help adding ADI amp to battery current sensing

    Hi Shine,

    I've actually had to throw away the DS2715 and I'm now trying to use the LTC4079 in my product.  I've redesigned the power system a little, but I think this may work much better.  It can also charge at 100mA which is what I need. 

  • RE: LTC4060 slow charge

    Hello,

    In general, slow charging NiCd cells makes termination a little more difficult.

    You are correct that –∆V termination is less reliable when charging slowly. Unfortunately, so is temperature-based termination. Your concern with –∆V termination may…