• LT3013 as drop in replacement for LT3012?

    Our product uses LT3012HFE#PBF  but these are unavailable in all distributors we have checked.

    Can we use LT3013 as a drop in for the LT3012 on the PC Assemblies as the PWRGD and CT pins on the PCB are No Connect as per the original design with the LT3012…

  • RE: 2 pc of LT3012 paralleled together (but no need for load sharing)

    >>"Can you use the approach using the LT3042 that I show in the image below?"
    unfortunately I need the wide input voltage range of the LT3012 (4...80V)

    If I understand you right the stability Problem does occur only at the time when both…

  • LT3010, LT3012 SHDN Timing

    I was considering using one of these linear regulators to power and LED.  I was wondering if the SHDN pin reacted fast enough to act as a PWM input at, say, 100Hz.

    Thanks,

    Dave

  • Whether LT3012/LT3012B is AEC Qualified? Not able to find AEC information in datasheet.

    Whether LT3012/LT3012B is AEC Qualified? Not able to find AEC information in datasheet.

  • RE: LTC7000IMSE's VCC failed

    If LTC7000 internal regulator were not adequate to provide power,  could we add LT3012 to charge bootstrapped capacitors. Question: If  LTC7000's VIN is also connected to LT3012's IN, could we turn on LT3012 before LTC7000 enabled? LTC7000's BST-TS will…

  • LTC2974 current sensing filter

    Hello, 

    I'm designing a controlled voltage source for 4 channels using a LTC2974 to control four LT3012 LDOs.

    My question it's about current sensing ports. In the datasheet defines how to measure the current with a shunt resistor that includes a filter…

  • RE: Use LT3010 to power LTC4020 INT_Vcc

    I am glad you asked this question because the use of the INTVcc preregulator in datasheet figure 9, figure 10 and the application circuit on p. 39. will not work.  Please use the following circuit instead.  Note that I have connected the ground pin of the…

  • RE: Question about θja of LTC4020

    Making an LTC4020 board with only 2 layers will be challenging.  It is difficult to include SGND and PGND planes with only 2 layers. 

    2oz. (71µm) copper is preferred for thermal and electrical conductivity.

    The main source of heat in the LTC4020 is…

  • To understand if Automotive Applications in LT/AD Datasheet means Whether it is AEC Qualified??

    To understand if Automotive Applications in LT/AD Datasheet means Whether it is AEC Qualified??

    Regarding the LDO, LT3012/LT3012B. Whether the LDO is AEC Qualified?

    Please Someone share any details u know Urgently!

  • TAGS LIST: Power Management

    LTM8045
    LTM8049
    LTM4651
    LTM4661
    LTM4686
    LTM4676
    LTM4686-1
    LTM4676A
    LTM4675
    LTM4677
    LTM4678
    LTM8062
    LTM8061
    LTM8052
    LTM8026
    LTM8056
    LTM8064
    LTM8054
    LTM8055
    LTM4600
    LTM4600HV
    LTM4608A
    LTM4604A
    LTM8032