• RE: HMC832 PLL

    Both HMC830 and HMC832 will meet these requirements but the application must utilize a tunable reference and manual tuning to meet the -60dBc spurious and hop time requirements.  I've attached an appnote on manual tuning.  With a fixed 50MHz reference Figure…

  • HMC830 Frequency Hopping - Direct LUT ?

    Hello,

    I'm working with the PLL VCO HMC830.

    I want to use a look-up table (LUT) for manual calibration, as decribe in "Frequency Hopping with Hittite PLLVCOs Application Note" (attached) (https : // www . hittite.com/content/documents/application_notes…

  • Recommended regulators for ADI PLLs and VCOs

    PLL Recommended regulator
    Low power standalone PLLs and the ADF4360-x narrowband PLL/VCO family (< 100 mA); e.g. ADF41xx, ADF42xx, ADF4360-x

    Use the ADP150 regulator; good performance, low cost.

    Use…

  • TAGS LIST: Clock and Timing

    LTC6953
    LTC6955
    LTC6957-1
    HMC6832
    HMC7043
    LTC6950
    LTC6954
    HMC987
    AD9576
    AD9508
    HMC1035
    HMC988
    HMC1033
    HMC1034
    HMC1032
    HMC1031
    ADN4670
    ADCLK944
    ADCLK950
    ADCLK948
    ADCLK846
    ADCLK954
    ADCLK946
    ADCLK854
    AD…
  • How do I use the SPI Mode Selection feature on HMC PLL's & PLLVCO's?

    This note discusses best practices for use of the Serial Port Interface (SPI) Mode selection feature of HMC PLL and PLLVCO product lines.

  • 'Must Knows' about ADI's family of Hittite PLL+VCO and Clock Timing products

    The attached FAQ document provides additional information on the use of the PLL+VCO and Clock Timing family of products.  Specifically,

    the applicable products are:

    HMC820LP6CE             HMC821LP6CE             HMC822LP6CE             HMC824LP6CE             HMC826LP6CE

    HMC828LP6CE             HMC829LP6…