• HMC702 Reg Map

    ADI if can provide HMC702 Register configuration guide file?

  • HMC702

    Hello,

    I manage to get HMC702 running in CW, but I don't manage to get the sweeping mode activated, no matter what I program into REG 14h.

    Maybe some internal clock forwarding is not set correctly.

    Could you provide example register values which activate…

  • HMC702: external ramp trigger

    Hello,

    could you tell me how to get sweeping mode with external ramp trigger on GPO3 running?

    Sweeping with internal trigger (ramp_repeat_en=1, ramp_trig_ext_en=0) works.

    Regards,

    Manuel

  • HMC702: Sweeping mode

    I manage to get HMC702 running in CW, but I don't manage to get the sweeping mode activated, no matter what I program into REG 14h.

    Maybe some internal clock forwarding is not set correctly.

    Could You provide example register values which activate…

  • HMC702 grounding

    The HMC702 PLL is a mixed analog/digital part with numerous grounds.  Should all the grounds be tied together to a single ground or should the analog and digital ground planes be kept separate and tied together using an inductor?

  • Questions about HMC702

    Hi,

    I have two questions about HMC702.

    1. Let me know the following spec of trigger signals to start sweep modes.

             Minimum pulse width, Low/High level threshold voltage

    2. Please take a look at the attachment. I have a question about the sweep_busy…

  • HMC702锁定检测

    目前寄存器设置如下:

    Reg 01h<14> = 1

    Reg 1Ah<9:0> = 40h ;     Reg 1Ah<11:10> = 1:1 ;     Reg 1Ah<13:12> = 1:0 (我在这里把LD—SDO接口强制设置在锁定检测状态,不需要其进行SDO串行数据输出);    Reg 1Ah<19:14> = 0h ;

    Reg 1Bh<3:0> = 2h ;

    按照以上设置,我用频谱仪检测到输出信号已经锁定后,LD-SDO接口始终没有输出一个高电平…

  • HMC702 and ADF5356?

    Hi, 

    I was wondering if the HMC702 and ADF5356 are compatible with each other? Can the ADF5356 be used as a VCO for HMC702 to sweep the entire band?

    Regards,

    Amin

  • RE: Noisefloor degradation of HMC702 Sweep Mode