• RE: HMC369 and HMC561 Phase noise issue

    Thanks Viktor

    As I stated in my answer to Marty, the active multiplier generating the 5 GHz from a 2.5 GHz phase-locked VCSO was run off the same supply voltage as the doubler from 5 to 10 GHz. This happened without the observed phase noise degradation…

  • Same s parameters for HMC 370 and HMC 369

    The s parameter files of HMC370 and HMC369 are same. Even though the file names are different the content is the same that of HMC369. Can you please upload the actual S parameters file of HMC370

  • TAGS LIST: RF and Microwave

    HMC928
    HMC929
    HMC931
    HMC932
    HMC933
    HMC934
    HMC935
    HMC247G
    HMC538
    HMC-C018G
    HMC-C025G
    HMC-C053G
    HMC-C584G
    HMC7056G
    HMC7054G
    HMC7053G
    HMC7056AG
    HMC642G
    HMC642AG
    HMC643G
    HMC644AG
    HMC647
    HMC647A
  • Equivalent Hours of HMC764LP6CE & HMC783LP6CE

    Dir Sir,

    I would like to know the equivalent hours of HMC764LP6CE & HMC783LP6CE. I cnn't find the information in the attached Reliability Report. How can I calculate that value?

    Best regards,

    Akira

  • RE: 36GHz RF oscillation signal source

    You need a PLL which drives a frequency doubler which drives an amplifier. Possible choices might be ADF4371 (PLL),  HMC1105 (frequency doubler) and HMC7229 (amplifier). These are not the only choices.

      PDF

  • RE: Query

    This part is EAR99. The attached RFIC selection guide lists the ECCN codes for all of ADI's RF products.