• Wrong LDO output voltage ADP122

    I am using ADP122 3V3 fixed output LDO which outputs 4.2V with no load.

    With 1k load the output goes down to 3.8V and with 0.3k back up to 4.3V.

    The input voltage is 4.8V and 1uF ceramic caps (with unidentified ESR) are used at the input and output…

  • RE: ADE9000 shield kit design

    Hello

    you could but you system performances would decrease

    ADuM6404 pin 15 (VISO) - you need 5V because ADP122 will use this value to power ADE9000 with 3.3V. This choise is linked to ADUM high noise at VISO pin compared to ADP.

    As a direct consequence…

  • RE: ADV7612 and ADV7511 reference design questions

    Hello, Guenter!

    Please explain what is the difference between ADV7612 and ADV7511 power supply requirements?

    Why on EVAL-ADV7612-7511 board power supplies for ADV7612 and ADV7511 are also different?

    1). Why for ADV7612 1.8V and 3.3V power supplies…

  • RE: 2 questions of power for ADN4605

    Hi Kaos,

    1. Pin C24 should connect to the DVcc supply which is 3.3V.

    2. The ADN4605 has four distinct supply pins (actually 5 including ground): VCC, DVCC, VTTI, and VTTO

    VCC, VTTI, VTTO can operate on over a nominal range of 2.5V to 3.3V, where DVCC…

  • ADI最新的EM流量计解决方案上线啦

    电磁流量计作为目前使用最为广泛的流量技术之一、液体流量测量中精度最高之一,你了解多少呢?

    先呈上【ADI最新的EM流量计解决方案】下载链接:http://h.analog.com/CN-APM-FLOWMETERff?ADICID=SOME_CN_P1657

    工业电磁流量计系统原理和典型架构

    电磁流量计的工作原理基于法拉第电磁感应定律。当垂直于磁场方向的导体以速度V做切割磁力线的运动时,导体的两端会产生一定的感应电动势E,通过检测该感应电动势的大小来计算液体流速变化。

    电磁流量计的特性包括无压力损耗…

  • TAGS LIST: Power by Linear

    LTM8045
    LTM8049
    LTM4651
    LTM4661
    LTM4686
    LTM4676
    LTM4686-1
    LTM4676A
    LTM4675
    LTM4677
    LTM4678
    LTM8062
    LTM8061
    LTM8052
    LTM8026
    LTM8056
    LTM8064
    LTM8054
    LTM8055
    LTM4600
    LTM4600HV
    LTM4608A
    LTM4604A
    LTM8032