• High-Performance MEMS IMU with Internal Moisture Barrier!

    As we all know, traditional conformal coating materials and curing methods have an adverse effect on Inertial MEMS sensors, such as gyroscopes, accelerometer and IMUs. This makes it difficult to protect these sensors with a robust moisture barrier,…

  • RE: Disable the magnetometer on ADIS16488A possible?

    Dear CWilson,

    The magnetometer on the ADIS16488A cannot be disabled, and there are currently no plans to make a version without it.

    However, have you considered the ADIS16489? It has similar performance to the ADIS16488, but without the magnetometer.

  • Question about NULL_CNFG for IMU device

    I have some questions about NULL_CNFG(Continous bias estimation) for IMU devices.

    #1, what's the function of NULL_CNFG? If you have some material to explain this function, please let me know.

    #2, About ADIS16480, Table3 says mention “NULL_CNFG” stall…

  • No Angle Outputs in the ADIS16480

    I can not read any Euler's angles or velocity (DELTVEL)! I mannaged to read the PROD_ID,temperature, pressure and gyro reading well, however for Euler's angles and velocity I'm only getting zeros.

    When I the the EVAL-ADIS (evaluation program…