When I set MSC_CTRL[10]=1 bit to initiate an internal self-test, I expected that MSC_CTRL[10] would remain high until the test completed and then the results could be read from DIAG_STAT. What I see instead is that MSC_CTRL is cleared to zero immediately…
The ADIS16385 has an optional point-of-percussion feature that translates accelerations as if the accels were located in one corner of the device. What is the untranslated XYZ location of the accelerometers within the ADIS16385 package ?
-Scott
Hi,
When communicating with the ADIS16385 over SPI, it looks like there is no checksum nor any other way to verify the reliability of the returned data. Is this in fact the case, or have I overlooked something in the datasheet. This seems to be the case…
The specs for the ADIS16385 (Table 1) indicate that linear-g bias compensation is turned on (MSC_CTRL[7] = 1). However, the power-on default for the 17385 is linear-g bias compensation off (MSC_CTRL[7] = 0).
If the linear-g bias compensation for gyros…
I am using the ADIS16385 in a new design and wanted to know if there are any export restrictions.
Q:
When I connect my ADIS16364 device to the EVAL-ADIS system, the gyroscopes are all pegged to 409 deg/sec and the device does not seem to be working. Any ideas?
-----------------------------------------------------------------------------------…
Hello ode45. Thank you for the clarification. I appreciate your insight on this and believe that you are correct. I plan to offer a more generic post for this, but wanted to provide a clear statement that all characterization on noise/stability/random…
The mechanical structure of the ADIS1636x and ADIS1640x IMUs does not support cost-effective repair of broken flex connectors. In light of this topic, here are some important points to consider when using these IMUs: