Hi Takahiro,
I have verified the error in the model. We will have to revise the model but this will take 2-4weeks time to complete. Is that okay with you?
I'll keep you posted once the model has been revised.
Regards,
May
Hi Takahiro,
I have verified the error in the model. We will have to revise the model but this will take 2-4weeks time to complete. Is that okay with you?
I'll keep you posted once the model has been revised.
Regards,
May
The ADG609 model has the same issue EE-cumulus noted above. I see that the ADG608 model is on rev 2, updated in 2018. The ADG609 one is still rev 1.0 from 2012. Any chance you've to a new version of the ADG609?