Hi,
How would ADF4360-1 behave when frequency is set to 2098 MHz (which is right on the edge of VCO bands) and REFin is drifting within +-1% (see picture from the datasheet below). Will it lose lock or switch the VCO band?
Regards,
Ivan
Hi,
How would ADF4360-1 behave when frequency is set to 2098 MHz (which is right on the edge of VCO bands) and REFin is drifting within +-1% (see picture from the datasheet below). Will it lose lock or switch the VCO band?
Regards,
Ivan
Hi,
Yes, this is correct for ADF4360-1. ADF4360-7 also uses same evaluation board and L1&L2, R25&R26 are required for ADF4360-7 to set VCO center frequency.
Regards,
Kudret
we are also facing same problem with ADF4350-1, V tune we are getting 1.6 to 2.5 for our frequency band of 2.2 to 2.3GHZ. we have checked your eavaluation board, the V tune is 0.7 to 1.7 with same band
kindly clarify
I have a question regarding the output impedance of pins RFout.A and RFout.B. There is a figure 22 of the matching network in the datasheet of ADF4360-1, which "provides an excellent match to 50 Ω over the operating range" [datasheet]. If I take the this…
Hi, I am currently using the ADF4360-9 to generate an LO ref in the range 146-152 MHz. My phase noise requirements are quite strict so have ended up running the VCO at double this and using the Divout f/2 output to get a slight improvement in noise performance…
I see the datasheet means that the output power is between -6dBm to -13dBm,this means the max output is -6dBm and I need this value,and I also use the recommended circuit at the output .Why do I get the output of 0.74dBm.Otherwise I see the datasheet…
I see the datasheet means that the output power is between -6dBm to -13dBm,this means the max output is -6dBm and I need this value,and I also use the recommended circuit at the output .Why do I get the output of 0.74dBm.Otherwise I see the datasheet…
Hello,
I am using ADF4360-9 as a transmitter with FM modulator on the VCO (Vtune).
To ensure reliable performances on the modulation, I would like to avoid switching VCO band when varying across the temperature range.
I have already reduced the inductor…
Hello
I have started using EV-ADF4360-9EB1Z through GUI provided with the evaluation board. As default the "RF Output Frequency" is set as 360 MHz. As per datasheet, primary output range is 64 to 400MHz. When i enter 200 as "RF Output Frequency…
Is the two output:RFAout and RFBout the differencial signals?Is the two signals' phase difference 180 deg ?
Or they are actually in-phase signals?