• ADA4862-3 Disable characteristics

    Hello,

    i miss the disable characteristics from the ADA4862-3 like it is mention in the AD8013 datasheet .

    It crosstalk and it off isolation is very important.

    Can you please publish this information? I need it for a video Board.

    thank u.

  • What is output of ADA4862 in power down?

    Is the output of the ADA4862-3 suitable for video mux applications? (i.e. high impedance when in shutdown)

    In either case what does the impedance of the output look like when in shut down.?

  • what is diffrence between AD4862 and ADA4862, why it does not show datasheet for AD4862 now

    few days back i had found the datasheet for AD4862 with application circuit of active low pass filter 27mhz,23db gain.....what know i am trying to find same AD4862 datasheet again on google, it disappear and results show ADA4862, how it happens

  • 3 wire 3 phase 115V(L-N) 380-665Hz prfc application

    Could you please suggest a analog pfc controller for 3 wire 3 phase, 115Vac, 380-665Hz, 380Vout, 800W, min 0,95 power factor?  I couldnt find vienna rectifier example or application note at Analog device.  My second alternative is 3 phase boost topology…

  • 3-Phase 4-wire in to 3-Phase 3 Wire

    How to give input connections to ADE7878 for 3-Phase 4 wire in to 3-PH 3 Wire?

  • what does the "-3" on the brand of ADV7390/1/2/3 and ADV7340/1/2/3 indicate?


    The latest revision of the encoder has the -3 version branded on it's package. The revision code of the encoder can be read back from register 0xBB bits 7:6. 01B indicates the latest revision.

    Further information on the change made to this version…

  • RE: ADF4355-3 Thermal Issue

    Hi,

    Reg10 keeps the temperature related coefficients within the reserved part. You can check figure 36 in datasheet. Reg10=0x00C026BA does not match with the reserved part of Register 10. You need to change register 10 as Reg10=0x600026BA. 

  • ADE7880 - 3 phase 3 wire delta configuration

    Hi,

    As per the ADE7880 datasheet pg. 43, in three phase three wire delta configuration, Phase B active, reactive and apparent powers are 0.

    So, I would like to know if there is a way to find out the Phase B power data in three wire delta configuration…

  • RE: LTC2901-3

    Greetings DBT,  

       If you are looking to add a Push button reset, refer to table 2 of www.analog.com/.../2901fb.pdf for the resistor values for R22 and R104.

    Thank you and best regards,

    Brad

  • ADE9078 3相3線Delta接的問題

    最近使用ADE9078的三相電能計量, 遇到以下的問題.

    問題介紹:

    1. 規格書有提到, 計算總功耗(有功, 無功和視在), 須將A相和C相的貢獻相加,

        而我運算的結果, 只有"有功"的算完的數值是正確的, 其餘無功以及視在的數值有落差.

    硬體介紹:

    三相是採用3線Delta, B相接地. 使用EVAL-ADE9078EBZ開發板+EVAL-SDP-CB1Z.

    電流部分使用CT(600:1)

    參數設定:

    VCONSEL設為1, ICONSEL設為0,