• AD9444: Exceeding the trace length

    On the date sheet designers are encouraged to use of modality LVDS. But it is
    recommended to keep the trace length less than 1 inch to 2 inches.
    I would have to use trace length of approximately 5 inches. E' possible to
    arrive to…
  • AD9444设计中出现的发热严重问题

    我在使用ADI9444型号产品时出现发热严重问题,后面附上我做的电路图,我的想法是用AD9444进行数据转换后然后传到FPGA中进行数据处理。前端使用的TI公司的差分运算放大器进行信号处理(在调试AD9444的时候前端的信号处理断开),我测量了一下电路的功耗在2W左右,中间的散热焊盘接到了模拟地上,整个设计参考的是datasheet中的CMOS MODE 进行的,其外围电路和参考设计不同的主要在模式引脚和DCS MODE引脚的处理上没有进行通过电阻拉低处理,而是直接将引脚拉倒要求的电压。

  • RE: AD9544 Configuration

    Yes, the AD9544 will accomplish this task.  You can use the 20MHz OCXO as the System Clock input and the 1PPS as a reference input.  When the 1PPS goes away, the device will enter holdover and the outputs will continue with the stability of the System Clock…