• AD7470 acquisition time

    The Data sheet for AD7470/AD7472 says acquisition time is *minimum* 135[ns]  in "Specification" section and then in the "Timing Specfications" section says this number is a max. I assume this is an error or am I missing something?

  • AD7470 Acquisition time

    Hi.

    I am confused about the acquisition time specification for the AD7470 - it's given to be 135ns. My understanding of ADC is that the acquisition time is related to the settling to 1LSB of the sampling circuit.  The circuit given in the data sheet…

  • PROTEUS library

    Can you please provide me with PROTEUS library for adc AD7470, Digipot AD 5204 and DDS AD 9835?

  • ADT7470 Status register 0x42

    Hello ADI support.

    I need you help.

    Then temperature dropped bellow Tmin and the fan controller AD7470 stops the Fan, but the Norm (bit 3 Register 0x42) doesn't asserted high) only corresponding fan[n] A 1 indicates that Fan [n]  has dropped below…

  • RE: ADC used for single-pulse conversion

    Hi Postino,

    Here are some list of ADC that could be suitable for your application. You may also wanted to check the ADI website and do a parametric search and put in parameters on the ADC that you wanted to search. Please refer to the link below.

  • TAGS LIST: Data Converters

    AD693
    AD5410
    AD5412
    AD5420
    AD5422
    AD5735
    AD5755
    AD5755-1
    AD5737
    AD5757
    AD5421
    AD421
    AD5758
    AD7569
    AD7669
    AD7868
    AD7869
    AD5593R
    AD5592R
    AD5940
    AD5941
    AD7293
    AD7294-2
    AD7292
    AD5590
    AD7294