• AD590

    Does any one have a working spice model for an AD590?

  • AD590S / AD590 Long Term drift

    Why is the long term drift in the Mil-Spec of the AD590S given as +/-0.1degC
    per month but in the datasheet as absolute value?
    For which lifetime is the long term drift given in the datasheet applicable?
    How can the temperature drift…
  • RE: pspice model for Ad590

    hi Divya,

    The diagram presented under the following link is appropriate for the ADI sensor. Please ensure that the resistor value is chosen to guarantee that the AD590 is supplied with at least 4V as otherwise operation of the AD590 can be compromised…

  • RE: ic with on chip cold junction compensation and amplification

    Hi,

    I am designing a universal analog input module with four channels.Each channel has to accept input from all thermocouple types,two ,three and four wire RTD,4 to 20mA ,and voltage signal(one at a time).In order to interface the thermocouples,I thought…

  • AD590 Accuracy

    Hello,

    I'm looking at using the AD590 (J grade) for a design and would like to know the final accuracy that the product has on delivery. Is the external calibration adjustment conducted by Analog Devices and so the part will have an accuracy of +/- 3…

  • RE: AD590 Rated Current Vs Peak Current

    The AD590 “rated current spec” is just the maximum current the part will draw and is 1uA times the maximum operating temperature in K. Peak current value would apply to a dynamic circuit that would draw high current for short periods of time that was…

  • RE: AD590 Moisture Sensitivity Level

    The AD590 MSL rating depends on the package in question:

    For AD590 8-ld SOIC, MSL rating = 1.

    For AD590 2-ld CQFP and 3-pin T0-52, MSL rating = N/A

    For the 2-ld CQFP and 3-pin T0-52 packages, both are housed in a ceramic hermetically sealed package…

  • AD590 Theta JC

    What is the AD590 Theta JC?

  • AD590 Long Term Drift

    What is the long term drift of the AD590?

  • AD590: Measuring the current output

    In the Test Center, we have a project on  measuring low temperatures on
    Aircraft. In this case, there is a need to measure temperature as low as
    -55 deg centigrade. Therefore we're interested in with your AD590
    product to get the solutions…