Original Question: Phase detector of the HMC807LP6CE does not work - 3 by csrmniirs
To Marty Richardson
Hi Marty !
Thanks a lot for your help. I've programmed in the proper sequence, but it does not work yet. Voltage on the pin 18 (CP) is zero, although REG 9 [23:21] and [20:18] is set to 010.
I have a question about the programming of some registers. In FAQ it is recommended: Reg 6 702F87h (configure the Delta-Sigma Modulator for Fractional Mode). What does it mean? Should I program first the recommended value 702F87h, and after that set required value or can I program my value right away? The same question is about other registers with recommended values.
The comparison frequency is 10 MHz, R=1.
Now the load sequence looks like follows:
reg0: 0x00000002
reg1: 0x02000002
reg2: 0x04000002
reg3: 0x060009B8
reg3: 0x06000A00 (two-stage programming is recommended in the HMC700 data Sheet)
reg4: 0x08000000
reg5: 0x0A000000
reg6: 0x0D08650E
reg7: 0x0E0009F4
reg8: 0x100063BE
reg9: 0x12900000
regB: 0x160010F4
Thank you in advance,
Best regards, Dmitry.