Q: When using the MAX2871's phase adjustment function, does the HOLD TIME of the MUX rising edge have to happen on the very first rising edge of the reference clock after the clock frequency is programmed…
For a single frequency, there may be multiple F and M combinations that exist; however, the correct F/M values will depend on the application. For quick response times, it is recommended to keep M constant…
The datasheet guarantees the output level of -4dBm to +5dBm for a single ended output power with an RF choke to supply. This does not mean that a resistive pull-up cannot be used but there is no guarantee…
If the MAX2871 is selecting the wrong VCO band, check if the VAS_TEMP or VCO auto select temperature compensation feature is enabled.
Enabling VAS_TEMP / VCO auto select temperature will fix the issue…
Question: I would like to know if there is a power output difference for the RFOUTB signals if we pull up the outputs with 50 ohm resistors or with RF chokes, as your data sheet indicates for single-ended…
Question: If I want to use an output single ended, would I use the 'P' pin? If so, what do I do with the 'N' pin? 50 ohms to ground? Does the 'N' pin's impedance have to match the 'P' pin's impedance?…
Q: I would like to make a phase lock module that can rapidly switch between different frequencies using the MAX2871. I checked the data sheet, and it mentions that it has a built-in VCO including 64 sub…
Bench Test Results: Using the MAX2871 EVKIT, the output power at room temperature is -4.09dBm. This measurement was taken from RF_OUTA+ with RF_OUTA- terminated with a 50ohm pad. The output was pulled…