Q. Does the phase offset of the refclk vary widely between power cycles and temperature changes? Does Maxim characterize for the phase offset from IC to IC? A. The delay from XTAL to CLKOUT is not characterized…
No, the MAX2769 has no EEPROM memory to retain settings. All ten configuration registers must be programmed after a power cycle. See Note 1 under the Electrical Characteristics table in the MAX2769, MAX2769B…
The noise figure of the MAX2769, when using the AGC gain setting is detailed according to the Cascaded Gain and Noise Figure vs. Temperature plot on sheet 5 of the datasheet. This characterization is done…
Q. Is it possible to drive two MAX2769 with one reference clock? A. It is possible to drive the MAX2769 with one reference clock. If the design is simply passing the X MHz refclk (XTAL pin) through without…
Unfortunately, No. Maxim does not offer any rad hard or space qualified devices and does not conduct any radiation testing. There are no plans to do so in the foreseeable future.
Q. Is the output clock (CLKOUT) phase-locked to the input clock (XTAL) on the MAX2769? A. The output clock CLKOUT is not “phase-locked” to the reference input clock XTAL.