Article How to find the I2C Read and Write slave addresses in MAX2112? The information in datasheet is not clear enough.

The MAX2112 has a 7-bit slave address that must be sent to the device following a START condition to initiate communication. The slave address is internally programmed to 1100 000
The write/read address is C0/C1 if ADDR pin is connected to ground. The write/read address is C2/C3 if ADDR pin is connected to VCC.​

The first 6 bits of the address are fixed (1100 00) while the seventh bit can be 0 or 1 depending upon if ADD is connected to GND or Vcc as follows

ADD pin is connected to GND
The 7 bit slave address will be 1100 000

so  a RD address will be  1100 0000 = 0xC0
similarly a WT address will be 1100 0001 = 0xC1

ADD pin is connected to Vcc
The 7 bit slave address will be 1100 001
​so a RD address will be  1100 0010 = 0xC2
similarly a WT address will be 1100 0011 = 0xC3