Q.
Can you provide information about the output voltage characteristic of the temperature sensor embedded in the AD8318?
---------------------------------------------------------------------------…
Question I want to control the PA by using this part in control mode. I tested the EVB
and got some results both measurement mode and control mode. The measurement
mode results are OK. But I can not…
Question I would to enlarge the frequency operating range up to 8.5GHz
1. Is it recommended by you even the device is up to 8GHz(refer to datasheet)
2. The influence on the electrical performance.…
Q.
The datasheet for the ADL5902 RMS detector shows only limited data above 5.8 GHz but the data sheet front page says it works up to 9 GHz. Can it really operate above 5.8 GHz?
------------------…
Q:
I want to increase the slope of the AD8319 log amp. Is there a formula to cacluate the resistor values needed?
----------------------------------------------------------------------------------…
Q.
Do you have any data on the long-term drift of RF Detectors?
------------------------------------------------------------------------------------------------------------
A.
The work that we…
Question: RMS detectors with a Linear-in-dB transfer function such as AD8362, AD8363, AD8364, ADL5902 and ADL5906 produces a peaking in detection voltage when driven by RF Bursts when there is no rms averaging…
Question: How can I figure out the output flatness vs. frequency of an RF Detector such as the AD8363
Answer:
Using the Slope and Intercept specs it is possible to get a sense for and RF Detector's…
Question: Is it possible to configure an RF Detector so that it can be switched between Measurement Mode and Controller Mode.
Answer: The attached schematic shows one possible implementation where the…