Q
Can I use the ADM1062's ADC from inputs VX1-5, VP1-4, VH and Temp sensor
without averaging?
I don't want to use the EEPROM for configuration. I want to initialize the
ADM1062 every start up over the SMBus. Can you tell me which register I have to
write for the configuration to read after it the ADC Value Register
continuously?
A
Yes, this is possible. There are several ADC registers to configure and then
do the readback, they’re documented in the AN-698, and there’s also another
Apps Note, AN-897, dealing with how to setup and configure and use the ADC as
well.
Please see files attached.