Locale Icon
English
EngineerZone
EngineerZone
Power Management
  • Log In
  • User
  • Site
  • Search
OR
Ask a Question
  • Forums

    Popular Forums

    • LTspice
    • Video
    • Power Management
    • RF & Microwave
    • Precision ADCs
    • FPGA Reference Designs

    Product Forums

    • Amplifiers
    • Clocks & Timers
    • Data Converters
    • Direct Digital Synthesis (DDS)
    • Energy
    • Interface and Isolation
    • MEMS Inertial Sensors
    • Power Management
    • Processors & DSP
    • Processors & Microcontrollers
    • Switches & Multiplexers
    • Sensors
    • Voltage References
    View All

    Application Forums

    • A2B Audio Bus
    • Audio
    • Automated Test Equipment (ATE)
    • Condition-Based Monitoring
    • Depth, Perception & Ranging Technologies
    • Embedded Vision Sensing Library
    • Motor Control Hardware Platforms
    • Precision Technology Signal Chains Library
    • Video
    • Wireless Sensor Networks Reference Library

    Design Center Forums

    • ACE Evaluation Software
    • ADEF System Platforms
    • Design Tools & Calculators
    • FPGA Reference Designs
    • Linux Software Drivers
    • Microcontroller no-OS Drivers
    • Power Studio Designer
    • Power Studio Planner
    • Reference Designs
    • Robot Operating System (ROS) SDK
    • Signal Chain Power (SCP)
    • Software Interface Tools
    • System Demonstration Platform (SDP) Support
  • Learn

    Highlighted Webinar

    Power Management Fundamentals II Session 4: Isolated Converters Explained

    What does isolation mean for power topologies? Let's review what galvanic isolation means and go through the terminology and standards. We'll explore isolation...

    Places

    • ADI Academy
    • ADI Webinars
    • Video Annex
    • Virtual Classroom

    Libraries

    • 3D ToF Depth Sensing Library
    • Continuous-Wave CMOS Time of Flight (TOF) Library
    • Embedded Vision Sensing Library
    • Gigabit Multimedia Serial Link (GMSL) Library
    • Optical Sensing Library
    • Precision Technology Signal Chains Library
    • Software Modules and SDKs Library
    • Supervisory Circuits Library
    • Wireless Sensor Networks Library

    Latest Webinars

    • Power Management Fundamentals II Session 6: Key Layout Considerations for Power
    • A 16T/16R X-Band Direct Sampling Phased Array Subsystem using Apollo MxFE
    • Power Management Fundamentals II Session 5: Deeper Look into Power Protection
    • Power Management Fundamentals II Session 4: Isolated Converters Explained
    • Maximize Your Power Regulator: Key Considerations for Thermal Performance
    View All Webinars
  • Community Hub

    Challenge Yourself!

      KCC's Quizzes AQQ296 about repairing an equation in a digital display

      1. Quote of this month: " When I die, I want to die like my grandfather who died peacefully in his sleep. Not screaming like all the passengers in his...

    View All

    What's Brewing

      Read a Blog, Take this Quiz for Another Chance to Win a Gift Card!

      Important: Read the blog first . The quiz questions are all based on the content from the blog: Too Much Chatter and Not Enough Talk - Learn the Benefits...

    View All

    Places

    • Community Help
    • Logic Lounge
    • Super User Program
    • Analog Dialogue Quiz

    Resources

    • EZ Code of Conduct
    • EZ How To Help Articles
    • Getting Started Guide
    • ADI: Words Matter
    • Community Help Videos
    View All
  • Blogs

    Highlighted Blogs

    ​​Functional Safety: A Driver of “Shift Left”​

    By Richard Obrien The key to faster, safer product development is to start smart - not catch up hard. In this blog, we’ll explore how the "Shift Left...

     

    The 5 Advantages of Hardware Fault Tolerance

    In IEC 61508, HFT stands for “ H ardware F ault T olerance”. HFT of one or higher means that there is no single fault that will cause a safety function...

    Latest Blogs

    • The Power Problem Inside Every AI Breakthrough: Part 1 of 3
    • Simplifying Stability with EVAL-KW4503Z: Part 1 of 3
    • Energy Transfer Considerations in Isolated SMPS: Part 2 of 4
    • Automating LTspice .NOISE Measurements with .STEP and .MEAS Directives: Part 2 of 3
    • ​​Channel Specification: The Key to GMSL Compliance​
    Read All Blogs

    ADI Blogs

    • EZ Spotlight
    • The Engineering Mind
  • ContentZone

    Visit ContentZone

    ContentZone

    Technical articles. Blogs. Videos. Your ADI content, all in one place.

    View ContentZone

    Featured Content

    Featured Content Title

    Blurb About Content

    View Content By Industry

    • Aerospace and Defense Systems
    • Automotive Solutions
    • Consumer Technology Solutions
    • Data Center Solutions
    • Energy Solutions
    • Healthcare Solutions
    • Industrial Automation Technology Solutions
    • Instrumentation and Measurement Solutions
    • Intelligent Building Solutions
    • Wireless Communication Solutions

    View Content By Technology

    • A2B Audio Bus
    • ADI OtoSense Predictive Maintenance Solutions
    • Dynamic Speaker Management
    • Gallium Nitride (GaN) Technology
    • Gigabit Multimedia Serial Link (GMSL)
    • Industrial Vision
    • Power Solutions
    • Precision Technology
    • RF
    • Sensor Interfaces
    • SmartMesh
Power Management
Power Management
Documents How to handle the sequence in ADP5052?
  • Q&A
  • FAQs/Docs
  • Members
  • Tags
  • Cancel
  • +Power FAQs
  • +AD8240: FAQ
  • +ADIsimPE: FAQ
  • +ADIsimPower: FAQ
  • +ADM1030: FAQ
  • +ADM1031: FAQ
  • +ADM1060: FAQ
  • +ADM1062: FAQ
  • +ADM1064: FAQ
  • +ADM1066: FAQ
  • +ADM1068: FAQ
  • +ADM1069: FAQ
  • +ADM1085: FAQ
  • +ADM1166: FAQ
  • +ADM1171: FAQ
  • +ADM1175: FAQ
  • +ADM1232: FAQ
  • +ADM12914: FAQ
  • +ADM13305-4: FAQ
  • +ADM1816: FAQ
  • +ADM202: FAQ
  • ADM2483_PV pin function
  • +ADM2484e: FAQ
  • +ADM2486: FAQ
  • +ADM2582E: FAQ
  • +ADM2587E: FAQ
  • +ADM2682E: FAQ
  • +ADM2687E: FAQ
  • +ADM3053: FAQ
  • +ADM3054: FAQ
  • +ADM3075E: FAQ
  • +ADM3202: FAQ
  • +ADM3251E: FAQ
  • +ADM3252E: FAQ
  • +ADM3307: FAQ
  • +ADM3483: FAQ
  • +ADM3485E: FAQ
  • +ADM3491: FAQ
  • +ADM4073T: FAQ
  • +ADM483E: FAQ
  • +ADM485: FAQ
  • +ADM6316: FAQ
  • +ADM6320: FAQ
  • +ADM696: FAQ
  • +ADM705: FAQ
  • +ADM706: FAQ
  • +ADM709: FAQ
  • +ADM7151: FAQ
  • +ADM7154: FAQ
  • +ADM7155: FAQ
  • +ADM7170: FAQ
  • +ADM8316: FAQ
  • +ADM869L: FAQ
  • +ADN8831: FAQ
  • +ADP-I2C-USB: FAQ
  • +ADP1043A: FAQ
  • +ADP1046A: FAQ
  • +ADP1047: FAQ
  • +ADP1048: FAQ
  • +ADP1050: FAQ
  • +ADP1051: FAQ
  • +ADP1055: FAQ
  • +ADP1074: FAQ
  • +ADP124: FAQ
  • +ADP125: FAQ
  • +ADP130: FAQ
  • +ADP150: FAQ
  • +ADP1600: FAQ
  • +ADP1607: FAQ
  • ADP160: FAQ
  • +ADP1612: FAQ
  • +ADP1621: FAQ
  • +ADP1741: FAQ
  • +ADP1829: FAQ
  • +ADP1851: FAQ
  • +ADP1870: FAQ
  • +ADP197: FAQ
  • +ADP198: FAQ
  • +ADP2108: FAQ
  • +ADP2118: FAQ
  • +ADP2138CB: FAQ
  • +ADP2140: FAQ
  • +ADP2303: FAQ
  • +ADP2384: FAQ
  • +ADP2386: FAQ
  • +ADP2441: FAQ
  • +ADP2504: FAQ
  • +ADP3040: FAQ
  • +ADP3302: FAQ
  • +ADP3330: FAQ
  • +ADP3338: FAQ
  • +ADP3339: FAQ
  • +ADP3623: FAQ
  • +ADP5014ACPZ-R7: FAQ
  • +ADP5046: FAQ
  • +ADP5050: FAQ
  • -ADP5052: FAQ
    • Are there any layout considerations when designing in the ADP5052?
    • Can the 4 bucks run at different frequency?
    • Can you supply PVIN1, PVIN2, PVIN3, PVIN4 and PVIN5 independently?
    • Can you use an inductor not specified in the datasheet?
    • Customer programmable fuses on ADP5053?
    • How can I disable one channel when I don't' use it?
    • How can I disable one channel when I don’t’ use it?
    • How to handle the sequence in ADP5052?
    • Is it possible to order a version with factory programmed output voltages?
    • Power Management solution for Altera Arria 10 FPGA
    • selecting an external FET?
    • Typical markets/applications for the ADP5052
    • Typical markets/applications for this device
    • What's the big differentiation for ADP5052 in the market?
    • What’s the big differentiation for ADP5052 in the market?
  • ADP5053: FAQ
  • +ADP5061: FAQ
  • +ADP5090: FAQ
  • +ADP5585: FAQ
  • +ADP5588: FAQ
  • +ADP5589: FAQ
  • +ADP7112: FAQ
  • +ADP7142: FAQ
  • +ADP7182: FAQ
  • +ADR01: FAQ
  • +ADR125: FAQ
  • +ADR127: FAQ
  • +ADR225: FAQ
  • +ADR3450: FAQ
  • +ADR365: FAQ
  • +ADR366: FAQ
  • +ADR381: FAQ
  • +ADR5045: FAQ
  • +Digital Power: FAQ
  • +DS1233-10+: FAQ
  • +DS1819AR-10-U+: FAQ
  • +DS1831: FAQ
  • +Efficiency Data: FAQ
  • +Generate Negative Supplies: FAQ
  • +Hand Soldering: FAQ
  • How should I connect ADM2483's Power Valid Pin (PVP) when not using it?
  • +LDO: FAQ
  • +Low Noise: FAQ
  • +LT1963: FAQ
  • +LT3045: FAQ
  • +LT3080: FAQ
  • +LT3081: FAQ
  • +LT3092: FAQ
  • +LT3380: FAQ
  • +LT3439: FAQ
  • +LT3508: FAQ
  • +LT3752: FAQ
  • +LT3932: FAQ
  • +LT3950: FAQ
  • +LT8277: FAQ
  • +LT8300: FAQ
  • +LT8304: FAQ
  • +LT8306: FAQ
  • +LT8336: FAQ
  • +LT8357: FAQ
  • +LT8361: FAQ
  • +LT8611: FAQ
  • +LT8619: FAQ
  • LT8631EFE#PBF: FAQ
  • +LT8645S: FAQ
  • +LT8646S: FAQ
  • +LT8648S: FAQ
  • +LT8650SHV-CSL#PBF: FAQ
  • +LT8650SP: FAQ
  • +LTC2953: FAQ
  • +LTC3105: FAQ
  • +LTC3114-1: FAQ
  • +LTC3127: FAQ
  • +LTC3221: FAQ
  • +LTC3350: FAQ
  • +LTC3355: FAQ
  • +LTC3588-1: FAQ
  • +LTC3637: FAQ
  • +LTC3643: FAQ
  • +LTC3779: FAQ
  • +LTC3869: FAQ
  • +LTC3897: FAQ
  • +LTC4070: FAQ
  • +LTC4121: FAQ
  • +LTC7890: FAQ
  • +LTC7891: FAQ
  • +LTM4638: FAQ
  • +LTM4644: FAQ
  • +LTM4655: FAQ
  • +LTM4661: FAQ
  • +LTM4668A: FAQ
  • +LTM4681: FAQ
  • +LTM4700: FAQ
  • +LTM4705: FAQ
  • +LTM8003: FAQ
  • +LTM8024: FAQ
  • +LTM8042: FAQ
  • +LTM8060: FAQ
  • +LTM8065: FAQ
  • +LTM8078: FAQ
  • +MAX14521E: FAQ
  • +MAX14720AEWA+: FAQ
  • +MAX14720EEWA+: FAQ
  • +MAX14750AEWA+: FAQ
  • +MAX15000AEUB+: FAQ
  • +MAX15003ATM+: FAQ
  • +MAX15004: FAQ
  • +MAX15005AAUA/V+: FAQ
  • +MAX15005AAUE+: FAQ
  • +MAX15005CAUE/V+: FAQ
  • MAX15021: FAQ
  • +MAX15021ATI+: FAQ
  • +MAX15021ATI/V+: FAQ
  • +MAX15023: FAQ
  • +MAX15026BETD+: FAQ
  • +MAX15027ATB+T: FAQ
  • +MAX15032ATA+T: FAQ
  • +MAX15035ETL+: FAQ
  • +MAX15046: FAQ
  • +MAX15058: FAQ
  • MAX15059: FAQ
  • +MAX15059AATE+: FAQ
  • +MAX15059BETE+: FAQ
  • +MAX15062CATA+: FAQ
  • +MAX15066: FAQ
  • MAX15102: FAQ
  • +MAX15102EWL+: FAQ
  • +MAX15108A: FAQ
  • +MAX1510ETB+T: FAQ
  • +MAX15157ATJ+: FAQ
  • +MAX15158: FAQ
  • +MAX1515ETG+: FAQ
  • +MAX15301AA02+CJK: FAQ
  • +MAX15301_AA01+CK_A1: FAQ
  • MAX15303: FAQ
  • +MAX15303EVKIT1#: FAQ
  • +MAX15303_AA00+CM_A1: FAQ
  • +MAX1556AETB+: FAQ
  • +MAX1595EUA50+: FAQ
  • +MAX16006BTG+: FAQ
  • +MAX16009TG+: FAQ
  • +MAX16012TT+T: FAQ
  • +MAX16013TT+: FAQ
  • +MAX16056: FAQ
  • +MAX1605ETT+: FAQ
  • +MAX16061: FAQ
  • +MAX16125WTEG00+T: FAQ
  • +MAX16169: FAQ
  • +MAX1634AEAI+: FAQ
  • +MAX16801BEUA+: FAQ
  • MAX16813: FAQ
  • +MAX16813ATP+: FAQ
  • +MAX16813ATP/V+: FAQ
  • MAX16813B: FAQ
  • +MAX16813BATP/V+: FAQ
  • +MAX16814AGP/VY+: FAQ
  • +MAX16814ATP/V+: FAQ
  • +MAX16814AUP/V+T: FAQ
  • +MAX16818: FAQ
  • +MAX16819ATT+: FAQ
  • +MAX16820ATT+: FAQ
  • +MAX16823ATE+: FAQ
  • +MAX16824AUE/V+: FAQ
  • +MAX16826: FAQ
  • +MAX16826ATJ+: FAQ
  • +MAX1682EUK+T: FAQ
  • MAX16833: FAQ
  • +MAX16833AUE/V+: FAQ
  • +MAX16833CAUE/V+CLM: FAQ
  • MAX16838: FAQ
  • +MAX16838BATP/V+: FAQ
  • +MAX1683EUK+T: FAQ
  • +MAX1687ESA+: FAQ
  • +MAX16903: FAQ
  • +MAX16907RATE/V+: FAQ
  • +MAX16910ATA9/V+CB: FAQ
  • +MAX16910CASA9/V+: FAQ
  • +MAX16910EASA8/V+T: FAQ
  • +MAX16930: FAQ
  • +MAX16931AGLR/VY+: FAQ
  • +MAX16935SAUE/V+T: FAQ
  • +MAX16936EVKIT#: FAQ
  • +MAX16956AUBA+: FAQ
  • +MAX16956AUBA/V+: FAQ
  • +MAX16961: FAQ
  • +MAX1698AEUB+: FAQ
  • MAX16990: FAQ
  • +MAX16990ATCC/V+: FAQ
  • +MAX16992ATCC/V+: FAQ
  • +MAX16993AGJF/VY+: FAQ
  • +MAX16998AATA+: FAQ
  • +MAX16999AUA05+: FAQ
  • +MAX17000AETG+: FAQ
  • +MAX1701EEE+: FAQ
  • +MAX17075: FAQ
  • +MAX1708EEE+: FAQ
  • MAX17105ETG+: FAQ
  • +MAX17105ETG+_T1: FAQ
  • +MAX17135ETJ+: FAQ
  • MAX17220: FAQ
  • MAX17220ALT+: FAQ
  • +MAX17220ALT+T: FAQ
  • +MAX17220ELT+T: FAQ
  • +MAX17221ELT+: FAQ
  • MAX17222: FAQ
  • +MAX17222ALT+: FAQ
  • MAX17222ELT+: FAQ
  • +MAX17222ELT+T: FAQ
  • +MAX17223: FAQ
  • +MAX17224ALT+: FAQ
  • +MAX17225ALT+: FAQ
  • +MAX17225ELT+: FAQ
  • MAX17225ENT+: FAQ
  • +MAX17225ENT+T: FAQ
  • +MAX17227AANT+: FAQ
  • +MAX17227AATA+: FAQ
  • +MAX17245ETERA+: FAQ
  • +MAX1724EZK30+: FAQ
  • MAX17250ANC+: FAQ
  • +MAX17250ANC+T: FAQ
  • +MAX17270ENE+: FAQ
  • +MAX17270_NE+_A1: FAQ
  • +MAX17290ETCC+: FAQ
  • MAX17292: FAQ
  • +MAX17292ETCF+: FAQ
  • +MAX17335X2EVKIT#: FAQ
  • +MAX1742: FAQ
  • +MAX1744: FAQ
  • +MAX17498BATE+: FAQ
  • MAX17501: FAQ
  • +MAX17501ATEVKIT#: FAQ
  • +MAX17502EATB+: FAQ
  • +MAX17502FATB+: FAQ
  • +MAX17502GATB+T: FAQ
  • +MAX17502HAUD+: FAQ
  • +MAX17503ATP+: FAQ
  • MAX17504: FAQ
  • +MAX17504AATP+: FAQ
  • +MAX17504ATP+: FAQ
  • +MAX17504A_TP+_A1: FAQ
  • MAX17505: FAQ
  • +MAX17505ATP+: FAQ
  • +MAX17509: FAQ
  • +MAX17531: FAQ
  • +MAX17536: FAQ
  • +MAX17541GATB+: FAQ
  • +MAX17544ATP+: FAQ
  • +MAX17546ATP+_T1: FAQ
  • MAX17552: FAQ
  • +MAX17552AATB+: FAQ
  • +MAX17552ATB+T: FAQ
  • +MAX17552A_UB+_A1: FAQ
  • +MAX17557: FAQ
  • +MAX17558ATJ+: FAQ
  • +MAX17559_CJ+_A1: FAQ
  • MAX17572: FAQ
  • +MAX17572ATC+: FAQ
  • MAX17574ATG+: FAQ
  • +MAX17574ATG+T: FAQ
  • +MAX17580ATC+: FAQ
  • +MAX17595ATE+: FAQ
  • MAX17596ATE+: FAQ
  • +MAX17596ATE+T: FAQ
  • +MAX17597ATE+: FAQ
  • +MAX17598: FAQ
  • MAX17599ATE+: FAQ
  • +MAX17599ATE+T: FAQ
  • +MAX17630: FAQ
  • +MAX17633AATP+: FAQ
  • +MAX17651AZT+: FAQ
  • MAX17681: FAQ
  • +MAX17681AATB+: FAQ
  • +MAX17681ATB+: FAQ
  • +MAX17681A_TB+_A1: FAQ
  • MAX17682: FAQ
  • +MAX17682ATP+: FAQ
  • +MAX17690ATE+T: FAQ
  • +MAX17690ATE/V+: FAQ
  • +MAX17710GB+: FAQ
  • +MAX1771ESA+: FAQ
  • +MAX17761: FAQ
  • +MAX18166: FAQ
  • +MAX1836EUT50#TG16: FAQ
  • +MAX1846EUB+: FAQ
  • +MAX1847: FAQ
  • MAX1896: FAQ
  • +MAX1896EUT+: FAQ
  • +MAX1932: FAQ
  • +MAX1945REUI+: FAQ
  • +MAX1951AESA+T: FAQ
  • +MAX1957EUB+: FAQ
  • +MAX19708: FAQ
  • +MAX20002: FAQ
  • +MAX20003C_TPA/VY+_A1: FAQ
  • MAX20004: FAQ
  • +MAX20004AFOA/VY+: FAQ
  • +MAX20004AFOC/VY+: FAQ
  • +MAX20004_FOB/VY+_B1: FAQ
  • +MAX20006AFDB/V+_T1: FAQ
  • +MAX20008AFOA/VY+_T1: FAQ
  • +MAX20012BATJL/V+T: FAQ
  • MAX20022: FAQ
  • +MAX20022ATIA+: FAQ
  • +MAX20022ATIA/V+: FAQ
  • +MAX20029ATIA/V+: FAQ
  • +MAX20029_TIA/V+_A1: FAQ
  • MAX20034ATI/VY+: FAQ
  • +MAX20034ATI/VY+_T1: FAQ
  • +MAX20034ATIR/VY+: FAQ
  • +MAX20040EVKIT#: FAQ
  • +MAX20048ATGA/VY+: FAQ
  • +MAX20050ATC/V+: FAQ
  • +MAX20050EVKIT#: FAQ
  • +MAX20051AAUD/V+: FAQ
  • +MAX20056BAUGA/V+: FAQ
  • +MAX20057ATIA/VY+T: FAQ
  • +MAX20059ATCA/VY+: FAQ
  • MAX20067GTJ/V+: FAQ
  • +MAX20067GTJ/V+T: FAQ
  • +MAX20070BGTJ/V+: FAQ
  • +MAX20075ATC/V+_T1: FAQ
  • +MAX20075ATCA/V+: FAQ
  • +MAX20075EVKIT#: FAQ
  • +MAX20076ATC/V+: FAQ
  • +MAX20076ATCA/V+: FAQ
  • +MAX20077ATCA/VY+: FAQ
  • +MAX20078ATE+: FAQ
  • +MAX20078ATE/V+T: FAQ
  • +MAX20078ATE/VY+T: FAQ
  • +MAX20078_TE+_A1: FAQ
  • +MAX20078_TE/V+_A1: FAQ
  • +MAX20090ATP/V+: FAQ
  • +MAX20090ATP/VY+: FAQ
  • +MAX20090BATP/V+: FAQ
  • +MAX20092ATJ/VY+: FAQ
  • +MAX20098ATE/V+: FAQ
  • +MAX20098ATEA/V+: FAQ
  • +MAX20098ATEA/VY+: FAQ
  • +MAX20098ATED/VY+: FAQ
  • +MAX20098ATEF/VY+: FAQ
  • +MAX20343BEWE+: FAQ
  • MAX20361AEWC+: FAQ
  • +MAX20361AEWC+_B1: FAQ
  • +MAX20410AFOA/VY+: FAQ
  • +MAX20419ATGA/V+: FAQ
  • +MAX20480ATEA/VY+: FAQ
  • +MAX20710EPL+T: FAQ
  • +MAX20730EPL+: FAQ
  • +MAX20733: FAQ
  • +MAX20734EPL+: FAQ
  • +MAX20735: FAQ
  • +MAX20743EPL+: FAQ
  • MAX20751: FAQ
  • MAX20751EKX+: FAQ
  • +MAX20751EKX+T: FAQ
  • +MAX20754ETMA1+: FAQ
  • +MAX20801AEVKIT#: FAQ
  • +MAX20801TPBA+: FAQ
  • +MAX20801TPBD+: FAQ
  • +MAX20812: FAQ
  • +MAX25203: FAQ
  • +MAX25206ATPA/VY+: FAQ
  • +MAX25210ASA8/V+: FAQ
  • +MAX25221BATJ/V+: FAQ
  • +MAX25240: FAQ
  • +MAX25254: FAQ
  • +MAX25262: FAQ
  • +MAX25601AATJ/VY+: FAQ
  • +MAX25610AATE/VY+T: FAQ
  • +MAX25611AATC/VY+: FAQ
  • +MAX25611DATC/VY+: FAQ
  • +MAX38640AELT+: FAQ
  • MAX38643AELT+: FAQ
  • +MAX38643AELT+T: FAQ
  • +MAX38643AENT+T: FAQ
  • +MAX38886ATD+: FAQ
  • MAX38888ATD+: FAQ
  • +MAX38888ATD+T: FAQ
  • +MAX38889AATE+: FAQ
  • +MAX38902AATA+: FAQ
  • +MAX38902EVKIT#: FAQ
  • +MAX38903AANL+: FAQ
  • +MAX38908ANL+: FAQ
  • +MAX5033: FAQ
  • MAX5035: FAQ
  • +MAX5035AASA+: FAQ
  • +MAX5035EASA/V+T: FAQ
  • +MAX5082: FAQ
  • +MAX5084ATT+T: FAQ
  • +MAX5085ATT+: FAQ
  • +MAX618EEE+: FAQ
  • +MAX6301: FAQ
  • +MAX6335: FAQ
  • +MAX6340_UK16+_A1: FAQ
  • +MAX634MJA/883B: FAQ
  • MAX6369: FAQ
  • +MAX6369KA+T: FAQ
  • +MAX6381XR26D3/V+T: FAQ
  • +MAX6389_XS16D3_A1: FAQ
  • MAX6412: FAQ
  • +MAX6412_UK16+_A1: FAQ
  • +MAX6420UK29+T: FAQ
  • +MAX6425: FAQ
  • +MAX6443: FAQ
  • +MAX6461: FAQ
  • +MAX651MSA/PR+_T1: FAQ
  • +MAX668EUB+: FAQ
  • +MAX668EUB_T1: FAQ
  • +MAX668EVKIT+: FAQ
  • +MAX6710KUT+: FAQ
  • +MAX6719AUTSVD3+T: FAQ
  • +MAX6722UTSDD3+: FAQ
  • +MAX6735A: FAQ
  • +MAX6735_KASYD3+_A1: FAQ
  • +MAX6747: FAQ
  • +MAX6753: FAQ
  • +MAX6759: FAQ
  • +MAX6764UT+: FAQ
  • MAX680CSA+: FAQ
  • +MAX6842DUKD0+T: FAQ
  • +MAX6867: FAQ
  • +MAX6975ATL+: FAQ
  • +MAX700CPA+: FAQ
  • +MAX705ESA+: FAQ
  • MAX706: FAQ
  • +MAX706SESA: FAQ
  • +MAX77324EWT00+: FAQ
  • +MAX77324EWTAD+: FAQ
  • +MAX774ESA+: FAQ
  • MAX77501EWV+: FAQ
  • +MAX77501EWV+T: FAQ
  • +MAX77503AEWC+T: FAQ
  • +MAX77503BEWC18+: FAQ
  • +MAX77504AAFC+T: FAQ
  • +MAX77542: FAQ
  • +MAX77597EVKIT#: FAQ
  • MAX775: FAQ
  • +MAX77643AANA+: FAQ
  • +MAX77655EWE+T: FAQ
  • +MAX77686: FAQ
  • +MAX77714EWC+: FAQ
  • +MAX77752AETL+: FAQ
  • +MAX77756: FAQ
  • +MAX77801ETP+: FAQ
  • +MAX77801_TP+_A1: FAQ
  • +MAX77812 EVALUATION KIT SOFTWARE: FAQ
  • +MAX77812AEWB+: FAQ
  • +MAX77812BEWB+: FAQ
  • +MAX77812CEWB+T: FAQ
  • MAX77812EWB+: FAQ
  • +MAX77812EWB+T: FAQ
  • +MAX77813EWP+: FAQ
  • +MAX77816AEWP+: FAQ
  • +MAX77816CEWP+T: FAQ
  • +MAX77827AEFD+_T1: FAQ
  • +MAX77827AEWC+: FAQ
  • +MAX77837: FAQ
  • +MAX77839: FAQ
  • +MAX77863AEWJ+: FAQ
  • +MAX77874: FAQ
  • +MAX786: FAQ
  • +MAX797MJE: FAQ
  • +MAX813LCPA: FAQ
  • +MAX8212CPA+: FAQ
  • +MAX821LUS+T: FAQ
  • +MAX823L: FAQ
  • +MAX823TEUK+: FAQ
  • +MAX824: FAQ
  • +MAX834EUK+: FAQ
  • +MAX8556ETE+: FAQ
  • +MAX8559ETAAJ+: FAQ
  • +MAX8569AETT+: FAQ
  • +MAX8570ELT+: FAQ
  • +MAX8570EUT+: FAQ
  • +MAX8597ETP+: FAQ
  • +MAX8607ETD+: FAQ
  • +MAX860MSA/PR2+_T1: FAQ
  • +MAX8625AETD+: FAQ
  • +MAX8647ETE+: FAQ
  • +MAX8664: FAQ
  • +MAX8668: FAQ
  • +MAX8686ETL+: FAQ
  • +MAX8794ETB+: FAQ
  • +MAX8815AETB+T: FAQ
  • +MAX8840ELT18+: FAQ
  • +MAX8858ETJ+: FAQ
  • +MAX8869EUE18+: FAQ
  • +MAX8881: FAQ
  • +MAX8887EZK18+T: FAQ
  • +MAX8892: FAQ
  • +MAX889RESA+: FAQ
  • +MAX8902AATA+: FAQ
  • +MAX8902AATA/V+: FAQ
  • +MAX8902B: FAQ
  • MAX8969AEWL53+: FAQ
  • +MAX8969AEWL53+T: FAQ
  • +MAXM15064AMB+T: FAQ
  • +MAXM15462AMB+: FAQ
  • +MAXM17502EVKIT#: FAQ
  • +MAXM17503ALJ+: FAQ
  • +MAXM17504EVKITAE#: FAQ
  • +MAXM17505: FAQ
  • +MAXM17515: FAQ
  • MAXM17532: FAQ
  • +MAXM17532AMB+T: FAQ
  • MAXM17537ALY#: FAQ
  • +MAXM17537ALY#T: FAQ
  • +MAXM17544ALJ+: FAQ
  • +MAXM17544EVKIT#: FAQ
  • MAXM17545: FAQ
  • +MAXM17545ALJ+T: FAQ
  • +MAXM17552: FAQ
  • +MAXM17575ALI#T: FAQ
  • +MAXM17575EVKIT#: FAQ
  • +MAXM17623AMB+T: FAQ
  • +MAXM17624AMB+: FAQ
  • +MAXM17635AMG+: FAQ
  • +MAXM17761ALI+: FAQ
  • +Measuring Signals: FAQ
  • +Package Information: FAQ
  • +Photosensitive: FAQ
  • +Power Management Support Intro: FAQ
  • +Switching Power: FAQ
  • +Temperature Grade: FAQ
  • +uPMU: FAQ
  • +VT1697SBFQX: FAQ

How to handle the sequence in ADP5052?

Question

How to handle the sequence in ADP5052?

Answer

Each channel in ADP5052 has individual precision enable with 0.8V accurate
turn-on threshold, which allows one channel’s output can be tied to other
channel’s enable input (through optional RC delay timer) to well control
power-up sequence. The PWRGD signal can be used along with enable pin to
generate the sequence as well.

It is possible to create a rough power-down sequence by precision enable to
program different UVLO threshold for each channel, a delay time between
channels can be produced when input power supply plug out and discharged
slowly. Active output discharge feature helps the output capacitor discharge
quickly to well control power down sequence. Just be noted it is difficult to
produce the power-down sequence if the power supply discharges too quickly.

Tags: 3GOX0051 power management adp5052
  • Share
  • History
  • Cancel
analog-devices logo

About Analog Devices

  • Who We Are
  • Careers
  • Newsroom
  • What We Do (Signals+)
  • Investor RelationsExternalLink
  • Quality & Reliability
  • Sales and Distribution
  • What's New on Analog.com
  • Contact Us

Find Help

  • Support
  • Resources
  • WikiExternalLink
  • Analog Dialogue
  • ADI Developer PortalExternalLink

myAnalog

Interested in the latest news and articles about ADI products, design tools, training, and events?

Go to myAnalog
  • Instagram page
  • Twitter page
  • Linkedin page
  • Youtube page
  • Facebook
  • Legal and Risk
  • Accessibility
  • Privacy Policy
  • Privacy Settings
  • Cookie Settings

©2026 Analog Devices, Inc. All Rights Reserved

analog-devices

About Analog Devices

Down Up
  • Who We Are
  • Careers
  • Newsroom
  • What We Do (Signals+)
  • Investor RelationsExternalLink
  • Quality & Reliability
  • Sales and Distribution
  • What's New on Analog.com
  • Contact Us

Find Help

Down Up
  • Support
  • Resources
  • WikiExternalLink
  • Analog Dialogue
  • ADI Developer PortalExternalLink

myAnalog

Interested in the latest news and articles about ADI products, design tools, training, and events?

Go to myAnalog
Instagram page Facebook Twitter page Linkedin page Youtube page
  • Legal and Risk
  • Accessibility
  • Privacy Policy
  • Privacy Settings
  • Cookie Settings

©2026 Analog Devices, Inc. All Rights Reserved