Question: How to configure the MAX20812 as a single output.
Answer: In order to configure the IC for a single phase implementation, there are a number of pins which will be unused. BST2 and LX2 can be left floating, but care is required to ensure that EN2 is grounded, otherwise, if EN2 is pulled high in any case, it may cause the device to be damaged due to no BST cap and BST overvoltage.