Correction of MAX38888 datasheet (Rev. 2; 10/18) errors in calculations for super capacitor voltage configuration:
- Page 9, under the section titled Super Capacitor Voltage Configuration, the second sentence reads “Recommended value for R2 is 499kΩ.”, this should be “Recommended value for R1 is 499kΩ” per Figure 1.
- Page 9, under the section titled Super Capacitor Voltage Configuration, the formula for setting the minimum super capacitor discharge voltage should be:
R3 = (R1 + R2) x ((VCAP MIN/0.475) -1)