Question:
Please advise MAX77812 delay time from EN goes Hi to Vout rising point.
Answer:
If the debounce timer setting is 64us (default)
90us(min) 120us-160us (typ) 220us(max)
If the debounce timer setting is changed from 64us (default) to 0us, the EN signal will bypass the debounce timer logic block.
As the result, the propagation delay is minimized.