Since the switching frequency of the MAX17531 is rather high, using it to supply power to the ADC will affect the performance of the ADC. The LDO and charge pump can be used to generate ±2.5V. MAX17651 can be used as the LDO and MAX1697 can be used as the inverting charge pump.