Supervisory IC datasheets usually provide Typical Operating Curve which shows the relationship between the transient duration (i.e how long the transient condition has to last before reset triggers) and the reset threshold overdrive (i.e how far the input voltage is below the reset threshold). For MAX823L, the relationship is shown below: