The thresholds are predetermined as a percentage of VTHM to VAVL. The resulting formula is a voltage divider across the resistors that are being used as shown below. Select the appropriate resistors to move the cold, cool, warm and hot thresholds to the desired range.
VTHM/VAVL = (R2||R3) / (R2||R3 + R1) |