When the charger is disconnected, VSYS cannot be regulated above VBATT. LDO cannot be made to operate in reverse mode.
In order to have VSYS > 3.7V at all times, even when VBATT < 3.7, and no other power source available, an external switching converter should be used to power from BATT to provide this additional power rail.