No, SPI communication is possible only for single MAX17853/2.
In series daisy connection of MAX17853/2, grounds are at different voltage levels as shown in below figure, hence SPI cannot be used for daisy chain serial communication.
No, SPI communication is possible only for single MAX17853/2.
In series daisy connection of MAX17853/2, grounds are at different voltage levels as shown in below figure, hence SPI cannot be used for daisy chain serial communication.