All default settings can be found in the part number decode section of the datasheet.
Based on either device registers being in default state or modified as needed, the current consumption changes accordingly.
With Vio supplied the quiescent current can be around 100uA and if it is not supplied, and PMIC by default is in normal power mode, the current can further reduce down to 40uA.