The LDO mode is only when VBatt < VSysMin.
After this point, VSYS = VBATT, and switch is fully on.
If charger is disconnected while VBAT < VSYSMIN, then the switch will quickly turn on fully.
The LDO mode is only when VBatt < VSysMin.
After this point, VSYS = VBATT, and switch is fully on.
If charger is disconnected while VBAT < VSYSMIN, then the switch will quickly turn on fully.