RepSOC is calculated by (RepCap + RepCapL) / FullCapRep. RepCapL may increase or decrease with current ADC, so RepSOC may increase even it's not charging. However, RepCap will not increase if it's not charging. So user could use SOC=RepCap / FullCapRep as SOC display.