Q: Some NiMH chargers with lower cell count (i.e. DS2711) allow for the detection of alkaline cells. Is this feature available in multi-cell (3+ in series) chargers like the DS2715?
A: No, the DS2715 does not integrate alkaline battery detection. Alkaline detection requires looking at each battery individually, and the multi-cell chargers look only at the full battery stack voltage.