For the DS2762 Li+ battery monitor absolute voltage accuarcy is most critical at the OV threshold, thus the offset error is tested at the OV threshold. Note 7 states that the offset error was tested at the OV threshold which is 4.35V and 4.275V for DS2762A and DS2762B, respectively.