During a battery temperature fault (thermistor enabled and THM pin reports cold or hot temperatures), the current, running charger timer is paused. After the fault is removed, the timer may resume or restart depending on which timer it is:
- Prequalification Safety Timer in Prequalification state
- Pauses during the fault and resumes counting after the fault is removed.
- Fast-Charge Safety Timer in Fast-Charge Constant-Current state
- Pauses during the fault and resets count after the fault is removed.
- Topoff Timer in Topoff state
- Pauses during the fault and resets count after the fault is removed.