The MAX17843 is capable of disabling some features and functions via the internal registers. Below are blocks you can shutdown by modifying the register configuration settings:
- Auto balancing switches disabled via AUTOBALSWDIS/BALSWEN[11:0]
- Thermistor Disable via ACQCFG[9:8]
- HV Charge Pump disable via HVCPDIS
- VBLKP and AUXIN measurements disabled via MEASUREEN[14:12]
- Cell Mismatch alert disabled via MSMTCH
- Watchdog disable via CBTIMER[3:0]