Equations to calculate the quantities in question are shown below:
where:
>FULL50 (mAH) = Characterization value in the EEPROM table (6A and 6B)
>AE/SE Active empty/standby empty = Calculated percentage based on temperature and all the active empty PPM values and temperature breakpoints.
>AS (%) is the age scalar value that the IC uses to learn as the cell ages.
>FULL (mAH) is a calculation of the expected full point at your current temperature based on FULL50 and all the PPM slopes stored in the table.