Article How Do I Adjust the Shutdown Timer in ModelGauge m5 Fuel Gauges?

The shutdown timer is implemented to prevent I2C activity from re-awakening the fuel gauge during the shutdown process. By default, the timer is set to 45 seconds, but a shutdown can be performed in anywhere between 1.4 seconds and 1.6 hours.

  • To set the timeout period between 45s and 1.6h, set the THR bits of the ShdnTimer register according to the formula: 
    • Shutdown Time-Out Period = 175.8ms × 2(8+THR)
  • To achieve shutdown in less than 45s, you can skip a portion of the timeout period by writing to the ShdnTimer register. When the SHDN command is sent, the CTR bits of ShdnTimer begin counting at 0 in 1.4s increments, and the shutdown is triggered one cycle after the count matches the threshold set by the THR bits. The default THR value of 0 corresponds to a count of 0x1F. To trigger a faster shutdown, follow this sequence:
    1. Set the SHDN bit in the Config register to begin the shutdown timer
    2. Write the ShdnTimer register to 0x001F - [delay(seconds) / 1.4]. Writing ShdnTimer to 0x001F triggers the fastest possible shutdown in about 1.4s.
    3. Ensure that ther is no I2C activity after the shutdown timer expires, or the fuel gauge will re-enter active mode.

 