Article For MAX17260 low-side current sensing, is CSPH left floating or tied to BATT?

CSPH should be tied to BATT when using low-side current sensing. The layout guide only shows critical layout concerns like Kelvin sensing for sense resistor and putting bypass capacitors as near the IC as possible and so CSPH, thermistor and I2C communications are omitted.

 

Before You Switch