Article In the DS2788EVKIT software as I increment each bit of the VGAIN register I would expect an increase of 1mV similar to RGAIN, why not?

The RGAIN has a resolution of 0.001 ohms, however the voltage resolution in this fuel gauge is 4.88mV. Therefore as you increase the value of bits written to the VGAIN register, the minimum voltage increase possible is 4.88mV.