  • Can you use the DS2740 with a sense resistor larger than 20mΩ?

    Yes, you can use a sense resistor larger than 20mΩ with the DS2740U. There is no limit to the sense resistor that you can use. The most important limit of the DS2740U is the full-scale range of the sense…
  • DS2740 firmware Related Questions

    1. How to convert the current register reading to mA ? CR X 312.5μA 2. How to Read Accumulated Register Data, mAh ? ACR x 312.5μAh 3. How to calculate the remaining charge time? The DS2740 can only read…
  • Questions related to DS2740 firmware

    1. How do I convert the reading of current register to mA CR x 312.5μA 2. How do I read the data of the accumulated register to mAh ACR x 312.5μAh 3. How do I calculate the remaining charging…