Original Question: An error message appeared and said " *** ERROR *** The circuit is too large to simulate with this version. Too many analog nodes" . by donadona999s
Hi there !
I just started using ADISIMPE and I have a question .
I tried to simulate AD8418A .
When I was using one AD8418A , there was no problem.
But tried to use two AD8418A , an error message apeared.
I can use more than two devices without using AD8418A.
But using more than two AD8418A , an error message apeared.
How can I use more than two AD81418A ?
Please help me to find out.
Best regards,
donadona
Verified Answer: RE: An error message appeared and said " *** ERROR *** The circuit is too large to simulate with this version. Too many analog nodes" . by LucaV
Dona,
the AD8418A is a current sense amplifier and the one in the ADIsimPE library has not yet been encrypted for node limitation expansion.
We are continuously adding encrypted models to the library so check the library from time to time.
To update the library either use the Auto-update function in ADIsimPE or you can find it at www.analog.com/ADIsimPE
To check if a model is encrypted right click on the IC after you place it on the canvas, select view/edit model.
If the model is encrypted you will see a line saying
-- START ENCRYPTION: "ANALOG DEVICES ENCRYPTION" as shown in the picture below.
In the meantime you can add an additional encrypted op-amp on your canvas (even if not connected to your circuit) and it may expand the limitation a bit for you to be able simulated 2xAD8418A
Question: RE: An error message appeared and said " *** ERROR *** The circuit is too large to simulate with this version. Too many analog nodes" . by donadona999s
Hi Lucav.
Thanks for your answer.
I understoof perfectly.
I really appriciate your support.
dona