Article How to determine the value of R3 for the compensation network in figure 3 of the datasheet of MAX1896?

For a MAX1896 application using ceramic output capacitors, a 10kΩ resistor with +/-1% tolerance should be used for R3 as shown in figure 3 of the datasheet.