For a MAX1896 application using ceramic output capacitors, a 10kΩ resistor with +/-1% tolerance should be used for R3 as shown in figure 3 of the datasheet.
When the MAX1896 is turned off, the soft-start capacitor is internally discharged to ground. The capacitor is discharged to ground via the reset switch. The datasheet specifies the maximum on-resistance…