The MAX17250 has a three-state ISET input pin used to select the inductor peak current limit (IPEAK), as shown in the Table.
ISET IPEAK (A)
VL 3.5
AGND 2.7
OPEN 1.85
ISET value is read when…
Question description:
==============================================
Customers observed LX switching waveform missing after Max17250 powered up with no load. They wanted to know whether this meets…
The device is going into current limit on the input side. For those specifications this part can only deal with approximately 650mA load current.
Our online simulation tool EE-Sim is helpful for further…